Válvulas > Acero Carbono > Mariposa High P. > Technical Data

TECHNICAL DATA

  TRIPLE OFF-SET BUTTERFLY VALVES  -  TECHNICAL DATA

 

 

PRESSURE/TEMPERATURE RATING (REF. ASME B16.34)

TEMPERATURE (°C)

MAXIMUM WORKING PRESSURE, kgf/cm2

CLASS 150

CLASS 300

CLASS 600

WCB

CF8M

WC9

WCB

CF8M

WC9

WCB

CF8M

WC9

-29 to 38

20.0

19.3

20.4

52.0

50.6

52.7

104.1

101.2

105.5

93

18.3

16.9

18.3

47.5

43.6

50.3

94.9

87.2

100.5

149

16.2

15.1

16.2

46.1

39.4

47.5

92.5

78.8

95.3

204

14.1

13.7

14.1

44.7

36.2

45.7

89.3

72.4

91.1

360

12.0

12.0

12.0

42.2

33.8

45.0

84.4

67.1

90.0

316

9.8

9.8

9.8

38.7

31.6

42.5

77.0

63.6

85.1

343

8.8

8.8

8.8

37.6

31.3

41.5

75.6

62.6

82.6

371

7.7

7.7

7.7

37.6

32.3

40.1

74.9

60.8

79.8

399

6.7

6.7

6.7

35.5

29.9

37.3

71.0

59.4

74.9

427

5.6

5.6

5.6

28.8

29.2

35.9

58.0

58.4

71.4

454

4.6

4.6

4.6

19.0

28.5

34.1

37.6

57.0

68.6

482

3.5

3.5

3.5

12.0

27.8

31.6

24.3

55.5

63.3

510

2.5

2.5

2.5

7.4

27.1

26.7

14.4

54.5

53.1

538

1.4

1.4

1.4

3.5

25.7

19.0

7.4

51.0

37.6

566

 

1.4(1)

1.4(1)

 

25.3

14.1

 

50.6

28.1

593

 

1.4(1)

1.4(1)

 

22.9

8.1

 

45.4

15.8

624

 

1.4(1)

1.4(1)

 

19.3

7.4

 

38.7

14.4

649

 

1.4(1)

1.4(1)

 

14.4

3.9

 

28.8

110.0

 NOTE: (1) For weld value only; the temperature rating of flanged end terminates at 538 deg. C.


 FLOW DATA
 Valve flow coeffient Cv defined as the flow of water at 60 deg F in gallons per minute (GPM) at a pressure of one pound per square inch (1 psi) accross a value.

 WHERE
 Q
   :  Flow rate (GPM)
 Cv :  Flow coeffient
 ΔP :  Pressure drop (psi)
 p   :  Density of fluid (p=62.4), water at 60 deg F)

 THEREFORE
 Q=Cv#ΔP

 FLOW COEFFICIENT VALUE (Cv)

 

3"

4"

5"

6"

8"

10"

12"

14"

16"

18"

20"

24"

150#

195

345

500

827

1523

2698

4032

5674

7880

10594

13292

19604

300#

195

345

500

786

1447

2563

3830

5390

7486

10064

12627

18624

600#

195

345

475

746

1374

2435

3640

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


 TORQUE DATA

Max, ΔP (kgf/cm2)

3"

4"

5"

6"

8"

10"

12"

14"

16"

18"

20"

24"

10.5(150PSIG)

2.8

4.9

6.8

11.0

19.3

29.8

51.2

61.7

86.5

143.7

181.8

272.5

20.0(285PSIG)

5.4

9.3

13.0

20.8

36.5

56.4

96.8

116.5

163.1

271.0

342.1

510.7

28.1(400PSIG)

7.6

13.0

18.2

29.1

52.3

81.5

134.2

169.3

236.8

386.0

495.1

735.1

42.2(600PSIG)

11.3

19.6

27.3

43.7

78.4

122.1

201.0

253.6

354.5

578.0

741.0

1098.9

52.0(740PSIG)

14.0

24.1

33.6

53.9

96.7

150.5

247.8

312.6

436.8

712.3

913.1

1353.5

104.1(1480PSIG)

36.4

66.2

90.1

144.9

284.6

449.4

642.5

 

 

 

 

 

 


 

 APPLICATION

  • NUCLEAR POWER PLANTS & POWER PLANTS
  • OIL REFINERIES & CHEMICAL PLANTS
  • PULP & PAPER, STEEL MILLS
  • OFFSHORE PLANTS
  • GAS PIPING & LOCAL AREA ENERGY SUPPLY SYSTEM
  • SHIP BUILDING

 INSTALLATION CAUTIONS

  • The valve is bi-directional and can be mounted in any position. However, it is recommended that the valve is horizontal to the stem and the inclined cone edge of disc faces towards the downstream. ( Refer to directional arrows and stem side )
  • If you want to use at temperatures below -48 deg C or above 426 deg C, the extension design shall be applied. In such case please contact the sales department.

 

 

Diseñado por Soporte Express Ltda.
Copyright © Supply Fitting Ltda. Todos los derechos reservados.